北京耐電壓強(qiáng)度擊穿測(cè)試儀廠家 產(chǎn)品優(yōu)勢(shì) Product advantage:
?西門子cpu中央單元處理器采集精度zui高zui穩(wěn)定
?無線藍(lán)牙控制擺脫距離困擾人機(jī)分離使用更加方便。
?雙向電壓電流干擾抑制技術(shù)
?新軟件 帶自檢功能 和預(yù)警提示功能增加電流電壓雙向判斷支持無線安全控制
?內(nèi)設(shè)漏電防護(hù)網(wǎng) 電弧自動(dòng)卸壓
?C++控制程序 結(jié)果更精準(zhǔn)
A SIEMENS CPU central processor to collect the highest accuracy of the most stable unit
A wireless Bluetooth control to get rid of problems more convenient man-machine separation distance.
A bidirectional voltage current interference suppression technology
A new software with a self-test function and warning function to increase the current voltage of the bidirectional wireless security control decision support
No internal leakage protection net arc automatic unloading
A new C++ control program more accurate results
北京耐電壓強(qiáng)度擊穿測(cè)試儀廠家 主要適用于固體絕緣材料如:塑料薄膜、樹脂、云母、陶瓷、玻璃、絕緣油、絕緣漆、紙板等介質(zhì)在工頻電壓或直流電壓下?lián)舸?qiáng)度和耐電壓時(shí)間的測(cè)試;電壓擊穿試驗(yàn)儀采用計(jì)算機(jī)控制,試驗(yàn)過程中可在線觀察試驗(yàn)曲線;自動(dòng)存儲(chǔ)試驗(yàn)條件及試驗(yàn)結(jié)果等數(shù)據(jù),并可存取、顯示、打印。
Mainly applicable to solid insulating materials such as: plastic film, resin, mica, ceramic, glass, insulating oil, insulating paint, paper and other media in the frequency of the voltage or DC voltage breakdown strength and voltage withstand test time; computer controlled by voltage breakdown testing instrument, the testing process can be observed online test curve; automatic storage test conditions and test data, and can access, display and print.
試驗(yàn)機(jī)軟件 Test machine software:
北京耐電壓強(qiáng)度擊穿測(cè)試儀廠家 軟件功能 Software function:
01、軟件平臺(tái):WINDOWS窗口操作平臺(tái),界面直觀,便于操作
02、曲線顯示:在實(shí)驗(yàn)過程中可以動(dòng)態(tài)顯示試驗(yàn)曲線
03、數(shù)據(jù)導(dǎo)出:可以對(duì)試驗(yàn)結(jié)果導(dǎo)入EXCEL表格
04、實(shí)驗(yàn)報(bào)告:可以人為設(shè)置報(bào)告名稱,并對(duì)實(shí)驗(yàn)報(bào)告進(jìn)行打印
05、試驗(yàn)方式:可以根據(jù)需求對(duì)直流試驗(yàn)和交流試驗(yàn)進(jìn)行靈活選擇
06、試驗(yàn)方法:可以根據(jù)需求自行選擇擊穿電壓、耐壓試驗(yàn)、梯度試驗(yàn)
07、參數(shù)設(shè)置:可以根據(jù)不同的試驗(yàn)方式及試驗(yàn)方法靈活設(shè)置所需的不同參數(shù)值
08、試樣設(shè)置:可對(duì)不同標(biāo)準(zhǔn)的試樣參數(shù)靈活設(shè)置
09、人員管理:設(shè)置用戶名及密碼,不同的操作員登入進(jìn)行不同的試驗(yàn),互不影響
10、標(biāo)準(zhǔn)選擇:含有不同標(biāo)準(zhǔn),可根據(jù)需求自行選擇
11、連續(xù)操作:連續(xù)操作試驗(yàn)時(shí),可直接在軟件里結(jié)束試驗(yàn),進(jìn)行二次試驗(yàn)
01, software platform: WINDOWS window operating platform, intuitive interface, easy to operate
02, curve display: in the experimental process, you can dynamically display the test curve
03, data export: you can import the test results EXCEL form
04 、 experiment report: you can set up the report name and print the experiment report
05, test way: can according to the demand for DC test and exchange test flexible choice
06 、 test method: the breakdown voltage, withstand voltage test and gradient test can be chosen according to the requirement
07 、 parameter setting: different parameters can be flexibly set according to different test methods and test methods
08. Sample setting: flexible setting of sample parameters of different standards
09, personnel management: set user name and password, different operators log in for different tests, without affecting each other
10, the standard choice: contains different standards, according to the needs of their choice
11, continuous operation: continuous operation test, you can directly end the test in the software, the two test
北京耐電壓強(qiáng)度擊穿測(cè)試儀廠家 技術(shù)要求 technical requirement :
01、輸入電壓: 交流 220 V
02、輸出電壓: 交流 0--50 KV ;
直流 0--70 KV ;(同類產(chǎn)品做到50kv)
03、電器容量: 10KVA
04、高壓分級(jí): 0--50KV 全程可調(diào)(采用高精度電壓采樣器件,取消了同類廠家由于電壓采樣精度不夠必須采用高壓分級(jí)的方式)
05、升壓速率:
100 V/S 200 V/S 500 V/S 1000 V/S 2500 V/S 3000 V/S (此項(xiàng)滿足標(biāo)準(zhǔn)里面極快速升壓試驗(yàn)要求)
備注:本產(chǎn)品采用的直流伺服電機(jī)加載減速機(jī)構(gòu),保證了標(biāo)準(zhǔn)里面關(guān)于極慢速試驗(yàn)和極快速試驗(yàn)的要求,(一般廠家為皮帶輪機(jī)構(gòu),誤差較大)保證用戶可以自由選擇升壓速率,是目前同類產(chǎn)品中*滿足國標(biāo)對(duì)于升壓速率要求的測(cè)試設(shè)備??梢愿鶕?jù)用戶需求設(shè)定不同的升壓速率
06、試驗(yàn)方式:
直流試驗(yàn):1、勻速升壓 2、階梯升壓 3、耐壓試驗(yàn)
交流試驗(yàn):1、勻速升壓 2、階梯升壓 3、耐壓試驗(yàn)
注:根據(jù)不同行業(yè)的標(biāo)準(zhǔn),我們可以根據(jù)用戶的要求,依據(jù)貴行業(yè)標(biāo)準(zhǔn),為您定制行業(yè)標(biāo)準(zhǔn)所需的特殊測(cè)試功能。
07、電壓試驗(yàn)精度: ≤ 1%
08、電極規(guī)格:1、片材電極 ¢25mm 兩個(gè) 片材電極 ¢75mm一只
2、管用電極 兩個(gè) 、一套。
09、過電流保護(hù)裝置應(yīng)有足夠靈敏度以保證試樣擊穿時(shí)在0.05S內(nèi)切斷電源。
10、本儀器采用先進(jìn)的無觸點(diǎn)原件勻速調(diào)壓方式,淘汰同類產(chǎn)品中機(jī)械傳動(dòng)升壓方式。
11、一次試驗(yàn)可以做5個(gè)試樣。備注:(同類產(chǎn)品一次試驗(yàn)只能做一個(gè)試樣)
12、耐壓時(shí)間設(shè)定:0-7小時(shí)(可通過軟件連續(xù)設(shè)定)
01 、 input voltage: AC 220 V
02 、 output voltage: AC 0--50 KV;
DC 0--70 KV; (similar products to achieve 50kV)
03, electrical capacity: 10KVA
04, high voltage classification: 0--50KV whole process adjustable (using high-precision voltage sampling device, canceled the same manufacturers, because the voltage sampling accuracy is not enough, must use high voltage classification method)
05, step up rate:
100 V/S 200 V/S 500 V/S 1000 V/S 2500 V/S 3000 V/S (this meets the latest standards, which are very fast step-up test requirements)
Note: This product uses the most advanced DC servo motor load reduction mechanism, ensure the latest requirements for very slow test and extremely fast test of the latest standards, (general manufacturer of belt pulley mechanism, error) ensure the user can freely choose the rate of pressure rise, similar products are currently only meet the national standard for test equipment boost rate requirements. Different boost rates can be set according to user requirements
06, test methods:
DC test: 1, uniform step-up 2, step 3, pressure test
AC test: 1, uniform step-up 2, step 3, pressure test
Note: according to the standards of different industries, we can tailor the special test functions required by your industry according to your standards.
07, voltage test accuracy: less than 1%
08, electrode size: 1, two 25mm of electrode sheet sheet electrode of a 75mm
2, the use of electrodes two, a set.
09, over-current protection device should be sufficient sensitivity to ensure that the sample breakdown, cut off the power supply in 0.05S.
10 、 this instrument adopts advanced contactless original uniform pressure regulation mode, and eliminates the mechanical drive step up mode in similar products.
11, a test can make 5 samples. Remark: only one sample can be used for the same product at one time
12 、 voltage setting time: 0-7 hours (can be set continuously by software)
北京耐電壓強(qiáng)度擊穿測(cè)試儀廠家 九級(jí)安全防護(hù)措施:
Nine level safety protection measures:
(1) 超壓保護(hù)
(1) over voltage protection
(2)試驗(yàn)過流保護(hù)
(2) test over-current protection;
(3)試驗(yàn)短路保護(hù)
(3) test short circuit protection;
(4)安全門開啟保護(hù)
(4) safety door opening protection;
(5)軟件誤操作保護(hù)
(5) software misoperation protection;
(6)零電壓復(fù)位保護(hù)
(6) zero voltage reset protection
(7)試驗(yàn)結(jié)束放電保護(hù)
(7) test discharge protection;
(8)獨(dú)立保護(hù)接地
(8) independent protective earthing;
(9)試驗(yàn)完成后電磁放電
(9) electromagnetic discharge after test completion
注意事項(xiàng) Matters needing attention:
1、試驗(yàn)過程中不能讓無關(guān)人員靠近,因本試驗(yàn)儀器可產(chǎn)生較高的電壓,未經(jīng)過培訓(xùn)的人員不能使用該設(shè)備。試驗(yàn)時(shí)要有監(jiān)護(hù)人員,不要單人使用。以防萬一發(fā)生意外情況。
2、長(zhǎng)時(shí)間不使用設(shè)備,在再使用時(shí),先讓儀器空載加壓一次,即把高壓電極的接線從均壓球上取下。查看計(jì)算機(jī)試驗(yàn)界面,看看高壓電壓是否正常。
3、試驗(yàn)中發(fā)生意外情況要及時(shí)切斷電源,問題處理后才能繼續(xù)試驗(yàn)。
4、設(shè)備安放要平穩(wěn),安放的地面要堅(jiān)固。是水泥地面以免產(chǎn)生共振。
5、該設(shè)備在使用中外殼要接保護(hù)地線,既設(shè)備外殼接大地,以保護(hù)操作人員和設(shè)備運(yùn)行的安全。
6、使用完設(shè)備后,要關(guān)掉系統(tǒng)各部分電源,不準(zhǔn)帶電插拔電源線。
7、要按規(guī)定的電源電壓接入設(shè)備。確保電路接線正確。否則會(huì)損壞設(shè)備。
8、該儀器需安置在室內(nèi),實(shí)驗(yàn)室應(yīng)整潔、干燥、無腐蝕性介質(zhì),非相關(guān)人員不要隨意操作。
9、不要讓設(shè)備電纜碰到尖邊,以免劃破電纜絕緣;不要讓電纜壓在重物之下,以免壓斷電纜引起火災(zāi);不要用電纜拉物體或用電纜捆綁物體,以免拉斷電纜使設(shè)備不能正常運(yùn)轉(zhuǎn)。
10、不要讓設(shè)備碰到水濺,腐蝕性氣體,可燃?xì)怏w和可燃物。如果不避免,可能火災(zāi)。
11、搬動(dòng)設(shè)備時(shí),要切斷設(shè)備電源,既要把插頭從插座中拔下。禁止搬動(dòng)設(shè)備時(shí)放倒設(shè)備或傾斜45°角以上。
12、不要在設(shè)備運(yùn)行時(shí)插拔設(shè)備的電源插頭。
13、儀器安裝時(shí)應(yīng)具有獨(dú)立的接地線。
14、在開機(jī)前,操作者要首先熟悉操作方法。
15、儀器不能在有強(qiáng)烈腐蝕性氣體及有顆粒雜質(zhì)的氣體環(huán)境中使用。
16、試驗(yàn)環(huán)境溫度15度到25度之間,相對(duì)濕度60%到70%之間。
17、試樣擊穿瞬間有火花產(chǎn)生并伴有聲響,屬正?,F(xiàn)象。
18、每次更換試樣或接觸高壓電極時(shí)必須用高壓放電棒對(duì)高壓電極進(jìn)行放電,放電時(shí)間5秒以上。
19、每次進(jìn)行試驗(yàn)前,必須檢查儀器接地。
1, the test process can not allow irrelevant personnel close to, because the test instrument can produce higher voltage, not trained personnel can not use the equipment. Test should be supervised, not single use. Just in case of an accident.
2, long time no use of equipment, in use again, let the equipment no-load pressure once, that is, the high-voltage electrode wiring from the pressure ball to take down. Check the computer test interface to see if the high voltage is normal.
3, the accident occurred in the test should be promptly cut off the power supply, the problem can be continued after testing.
4, equipment should be stable, the ground should be solid. It is better to cement the floor to avoid resonance.
5, the equipment in use, the shell should be connected to protect the ground wire, both the equipment casing grounding, in order to protect the operation of personnel and equipment safety.
6, after using the device, to turn off the power supply system parts, no live plug-in power line.
7, according to the specified supply voltage access equipment. Make sure the circuit is properly connected. Otherwise it will damage the equipment.
8, the instrument should be placed indoors, the laboratory should be clean, dry, non corrosive media, non related personnel should not operate at will.
9, don't let the equipment cable touches the sharp edges, so as not to cut the cable insulation; don't let cable under heavy pressure in pressure, so as not to break the cable caused by fire; do not use cable objects or bundled with cable, so as to avoid breaking the cable to make the equipment can not operate normally.
10, do not let the equipment touch water splash, corrosive gas, flammable gas and combustible matter. If not avoided, a fire may be avoided.
11, when moving equipment, to cut off the equipment power supply, both should plug out from the socket. When moving equipment, lower the equipment or tilt 45 degrees above.
12, do not plug in the device when the device is running.
13, the instrument should be installed with independent ground wire.
14, before the boot, the operator must first familiar with the operation method.
15, the instrument can not be used in a strong corrosive gas and particulate impurities in the gas environment.
16, test environment temperature between 15 degrees to 25 degrees, relative humidity between 60% and 70%.
17, the sample breakdown spark occurs immediay, accompanied by sound, is a normal phenomenon.
It is necessary to discharge on the high voltage electrode with high voltage discharge rod 18, each change of the sample or the high voltage electrode contact, discharge time of 5 seconds.
19 before each test, the instrument must be checked for grounding.
我公司專業(yè)生產(chǎn)、銷售實(shí)驗(yàn)室試驗(yàn)儀器設(shè)備,周到的服務(wù)流程讓您滿意,及時(shí)的售后流程讓您安心,如需請(qǐng)致電詳談
詳詢:
Our company specializes in the production and sale of laboratory testing instruments and equipment, and thoughtful service process to your satisfaction, timely after-sales process to make you feel at ease, if necessary, please call details
Detailed inquiry: :