薄膜表面電阻率測試儀
型號:BEST-121
一、薄膜表面電阻率測試儀 產(chǎn)品介紹:
本儀器采用了美國Intel公司的大規(guī)模集成電路,使儀器體積小、重量輕準(zhǔn)確度高。數(shù)字液晶直接顯示電阻值和電流。
二、特點:
本儀器具有精度高、顯示迅速、穩(wěn)定性好、讀數(shù)方便, 適用于防靜電產(chǎn)品 如防靜電鞋、防靜電塑料橡膠制品、計算機(jī)房防樹脂云母體積表面電阻率測試儀靜電活動地板等電阻值的檢驗以及絕緣材料和電子電器產(chǎn)品的絕緣電阻測量。本儀器除能測電阻外,還能直接測量電流如電子器件暗電流等
This instrument has high precision, fast display, good stability and convenient reading. It is suitable for testing the resistance of anti-static products such as anti-static shoes, anti-static plastic rubber products, computer room anti-resin mica volume surface resistivity tester, electrostatic movable floor, insulation materials and electronic and electrical products. Quantity. Besides measuring resistance, the instrument can measure current directly, such as dark current of electronic devices.
三、主要標(biāo)準(zhǔn):
GB/T 1410-2006 《 固體絕緣材料體積電阻率和表面電阻率試驗方法》
ASTM D257-99 《絕緣材料的直流電阻或電導(dǎo)試驗方法》
GB/T 2439-2001《硫化橡膠或熱塑性橡膠 導(dǎo)電性能和耗散性能電阻率的測定》
GB/T 10581-2006 《絕緣材料在高溫下電阻和電阻率的試驗方法》
GB/T 1692-2008 《硫化橡膠絕緣電阻率的測定》
GB/T 12703.4-2010 《紡織品 靜電性能的評定 第4部分:電阻率》
GB/T 10064-2006《測定固體絕緣材料絕緣電阻的試驗方法》
四、典型應(yīng)用
1、測量絕緣材料電阻(率)
2、測量防靜電材料的電阻及電阻率
3、測量計算機(jī)房用活動地板的系統(tǒng)電阻值
4、測量防靜電鞋、導(dǎo)電鞋的電阻值
5、光電二極管暗電流測量
6、物理,光學(xué)和材料研究
五、技術(shù)指標(biāo)
1、電阻測量范圍: 0.01×104Ω ~1×1018Ω。
2、電流測量范圍: 2×10-4A~1×10-16A
3、顯 示 方 式:液晶、電阻、電流雙顯示
4、內(nèi)置測試電壓: 10V 、50V、100V、250V、500V、1000V(任意切換);
5、基本準(zhǔn)確度:≤1%;
6、使用環(huán)境:溫度:0℃~40℃,相對濕度<80%
7、供電形式:AC 220V,50HZ,功耗約5W
8、全自動測量、體積小、重量輕、準(zhǔn)確度高,電阻、電流雙顯示,性能好穩(wěn)定、讀數(shù)方便
9、所有測試電壓(10V/50V/100/250/500/1000V) 測試時電阻結(jié)果直讀
10、配置:
主機(jī):一臺
屏蔽箱+電極:一套
測試線:五條
說明書+合格證+保修卡:各一份
六、工作原理
根據(jù)歐姆定律,被測電阻Rx等于施加電壓V除以通過的電流I。傳統(tǒng)的高阻計的工作原理是測量電壓V固定,通過測量流過取樣電阻的電流I來得到電阻值。從歐姆定律可以看出,由于電流I是與電阻成反比,而不是成正比,所以電阻的顯示值是非線性的,即電阻無窮大時,電流為零,即表頭的零位處是∞,其附近的刻度非常密,分辨率很低整個刻度是非線性的。又由于測量不同的電阻時,其電壓V也會有些變化,所以普通的高阻計是精度差、分辨率低。
According to Ohm's law, the measured resistance Rx is equal to the applied voltage V divided by the current I. The traditional high resistance meter works on the principle that the voltage V is fixed and the resistance value is obtained by measuring the current I flowing through the sampling resistance. Ohm's law shows that the current I is inversely proportional to the resistance, not directly proportional to it, so the display value of the resistance is nonlinear, that is, when the resistance is infinite, the current is zero, that is, the zero position of the head of the meter is infinite, the scale near it is very close, and the resolution is very low. The whole scale is nonlinear. And because the voltage V of the resistor varies a little when measuring different resistors, the common high resistor meter has poor precision and low resolution.
七、試驗應(yīng)滿足下例要求:
1、測試電壓范圍應(yīng)包括:100V~500V
2、測量范圍應(yīng)包括:1×106Ω~1×1017Ω
3、阻值大于1012Ω時,測量誤差應(yīng)小于±20%,阻值不大于1012Ω時,測量誤差應(yīng)小于±10%。
4、輸入接線的絕緣電阻應(yīng)大于儀器輸入電阻的100倍。
5、測試時試樣及測量導(dǎo)線應(yīng)有良好。
6、儀器應(yīng)定期進(jìn)行校驗。
八、安全注意事項
1. 使用前務(wù)必詳閱此說明書,并遵照指示步驟,依次操作。
2. 請勿使用非原廠提供之附件,以免發(fā)生危險。
3. 進(jìn)行測試時,本儀器測量端高壓輸出端上有直流高壓輸出,嚴(yán)禁人體接觸 ,以
免觸電。
4. 為避免測試棒本身絕緣泄漏造成誤差,接儀器測量端輸入的測試棒應(yīng)盡可 能懸
空,不與外界物體相碰。
5. 當(dāng)被測物絕緣電阻值高,且測量出現(xiàn)指針不穩(wěn)現(xiàn)象時,可將儀器測量線屏 蔽端夾子接 上。 例如: 對電 纜測纜 芯與 纜殼的 絕緣 時,除 將被 測物兩 端分 別接于 輸入 端與高壓 端, 再將電 纜殼 ,芯之 間的 內(nèi)層絕 緣物 接儀器 “G”,以消 除因 表面漏 電而 引起的測 量誤 差。也 可用 加屏蔽 盒的 方法, 即將 被測物 置于 金屬屏 蔽盒 內(nèi),接 上測 量線。
九、安全注意事項:
開機(jī)之前,敬請仔細(xì)閱讀本 使用指南,以防止出現(xiàn)對操作人員的意外傷害或?qū)x器的損壞等的事件。
操作前,請閱讀“安裝與設(shè)置”,保證對儀器各部件的正確安裝與連接。
在*操作前,務(wù)必請有操作經(jīng)驗的人員進(jìn)行指導(dǎo),防止誤操作造成意外事件的發(fā)生。
電擊危險: 確保在安裝或維修該儀器之前使所有導(dǎo)線斷電,防止在帶電情況下,對人員或設(shè)備造成傷害。
十、售后管理:
我公司實現(xiàn)計算機(jī)化管理,實行客戶定期回訪制度,定期復(fù)查設(shè)備的工作情況,定期指導(dǎo)用戶對設(shè)備進(jìn)行保養(yǎng)和檢測,以便設(shè)備正常運轉(zhuǎn),跟蹤客戶的設(shè)備使用情況,以便及時對設(shè)備進(jìn)行維護(hù)。