國產(chǎn)電氣擊穿強度試驗儀
擊穿電壓breakdown voltage
1.(在連續(xù)升壓試驗中)在規(guī)定的試驗條件下,試樣發(fā)生擊穿時的電壓。
2.(在逐級升壓試驗中)試樣承受住的zui高電壓,即在該電壓水平下,整個時間內(nèi)試樣不發(fā)生擊穿。
國產(chǎn)電氣擊穿強度試驗儀 Gas dielectric breakdown
Under the action of electric field, gas molecules collide and ionize, which results in the penetrating discharge between electrodes. There are many factors affecting the penetrating discharge, such as the applied voltage, the shape of the electric plate, the nature and state of the gas, etc. Gas dielectric breakdown is often caused by DC voltage breakdown, power frequency voltage breakdown, high pressure electric breakdown, impulse voltage breakdown, high vacuum electric breakdown, negative electric gas breakdown and so on. Air is a good gas breakdown. Edge material, high ionization and breakdown field strength, can quickly restore the insulation performance after breakdown, and is non-flammable, non-explosive, non-aging, non-corrosive, so it has been widely used. In order to provide the design basis for the air gap distance of high-voltage transmission lines or substations (how high the high-voltage transmission lines should be off the ground), it is necessary to carry out the industrial frequency breakdown test of long air gap.
標(biāo)準(zhǔn)GB/T1408的部分規(guī)定了測量固體絕緣材料工頻(即48Hz~62Hz)短時電氣強度的試驗方法.本部分規(guī)定了用液體和氣體作為固體絕緣材料試驗時的浸漬劑或周圍媒質(zhì),但不適用于液體和氣體的試驗.
注:本部分包括測定團體絕緣材料表面擊穿電壓的方法.
技術(shù)指標(biāo)
1、輸入電壓AC220V50Hz
2、輸出電壓AC:0~20kV;DC:0~20kV
3、輸出功率2kVA
4、測量范圍AC~20kV;DC~20kV
5、測量誤差≤2%
6、升壓速率1kV/s~5kV/s
7、耐壓時間0~6H
8、漏電流1~30mA可由計算機軟件自由進行設(shè)定
9、電源交流220V±10%的單相交流電壓和50Hz±1%的頻率
10、試驗環(huán)境溫度:15~30℃,相對濕度:0~85%能夠穩(wěn)定運行。
11、外形尺寸長×寬×高:800mm×800mm×1450mm
12、設(shè)備自重100Kg
Technical index
1. Input voltage AC220V50Hz
2. Output voltage AC:0-20kV; DC:0-20kV
3. Output Power 2kVA
4. Measurement range AC-20kV; DC-20kV
5. Measurement error <2%
6. Boost Rate 1 kV/s~5 kV/s
7. Voltage withstanding time 0-6H
8. Leakage current of 1-30 mA can be set freely by computer software.
9. Single-phase AC voltage of 220V+10% and frequency of 50Hz+1% AC power supply
10. The test environment temperature is 15-30 C and the relative humidity is 0-85%.
11. Shape dimension: length * width * height: 800mm * 800mm * 1450mm
12. Equipment self-weight 100Kg
試樣的狀態(tài)
a) 試樣的厚度和均勻性,是否存在機械應(yīng)力;
b) 試樣預(yù)處理,特別是干燥和浸漬過程;
c) 是否存在孔隙、水分或其他雜質(zhì)。
厚樣品的試驗
當(dāng)有規(guī)定時,厚度超過 3mm 的板材和片材應(yīng)單面機加工至(3. 0 士 0. 2) mm. 然后,試驗時將高壓電極置于未加工的面上。
注:為了避兔網(wǎng)絡(luò)或因受現(xiàn)有設(shè)備限制,必要時可以根據(jù)需要,通過機加工把試樣制備成更小的厚度。
熱固性材料
應(yīng)用(1. 0土0.1) mm厚的試樣,這些試樣可以按ISO 295: 1991壓塑成型或按ISO 10724: 1994注塑成型,其表面尺寸應(yīng)足以防止閃絡(luò)(見5. 3. 2)。
注:如果不能應(yīng)用(1. 0土0. 1) mm厚的試樣,則可用(2. 0土O. 2) mm厚的試樣。
充填膠
電極是兩個金屬球,每個球的直徑為(12. 5 ~ 13)mm. 水平同軸放置,除另有規(guī)定外,彼此相隔(1. 0土0.1) mm,并都嵌入充填膠內(nèi) 。 應(yīng)注意避免出現(xiàn)空隙,特別避免兩電極間的空隙。 由于用不同的 電極距離得到的結(jié)果不能直接相比,因此必須在材科規(guī)范的試驗報告中注明間隙距離.
試驗條件
a) 施加電壓的頻率、被形和升壓速度或加壓時間;
b) 環(huán)境溫度、氣壓和濕度;
c) 電極形狀、電植尺寸及其導(dǎo)熱系數(shù);
d) 周圍媒質(zhì)的電、熱特性。
滿足標(biāo)準(zhǔn):
1、GB1408.1-2006《絕緣材料電氣強度試驗方法》
2、GB1408.2-2006《絕緣材料電氣強度試驗方法
第2部分:對應(yīng)用直流電壓試驗的附加要求》
3、GB/T1695-2005《硫化橡膠工頻擊穿電壓強度和耐電壓的測定方法》
4、GB/T3333 電纜紙工頻電壓擊穿試驗方法
5、HG/T 3330絕緣漆漆膜擊穿強度測定法
6、GB12656 電容器紙工頻電壓擊穿試驗方法
7、ASTM D149《固體電絕緣材料工業(yè)電源頻率下的介介電強度的試驗方法》
Structural characteristics:
V voltage breakdown tester adopts vertical box structure, which greatly saves the space occupied in the laboratory. The foot adopts pulley structure, which is convenient to move and put. It avoids the horizontal equipment produced by similar manufacturers. It needs another installation platform when it is installed. It occupies a large space and is inconvenient to move. This product adopts DC servo motor loading and decelerating mechanism, which guarantees the latest requirements of the latest standard on extremely slow speed test and very fast test, and guarantees that users can freely choose the boost rate.
九級安全防護措施:
(1) 超壓保護
(2)試驗過流保護
(3)試驗短路保護
(4)安全門開啟保護
(5)軟件誤操作保護
(6)零電壓復(fù)位保護
(7)試驗結(jié)束放電保護
(8)獨立保護接地
(9)試驗完成后電磁放電
Test methods:
1. Breakdown test, voltage withstand test or step test of insulating sample in air;
2. Breakdown test, voltage withstand test or step test of insulating sample immersed in oil;
Note: Other test methods can be customized according to user's requirements.
試驗軟件:
1、試驗軟件是我公司研發(fā)的功能強大、操作簡單、顯示直觀的試驗軟件系統(tǒng);
2、采用計算機控制通過人機對話方式,完成對絕緣介質(zhì)工頻電壓擊穿,工頻耐壓試驗;
3、本儀器在試驗過程中可對升壓擊穿過程繪制實時曲線,每次試驗的升壓曲線都由不同顏色構(gòu)成,試驗結(jié)束后可疊加對比材料的試驗數(shù)據(jù)重復(fù)性;
4、可以隨時調(diào)取當(dāng)前及歷史試驗數(shù)據(jù)進行查看,編輯及修改參數(shù);
5、試驗過程中可以隨時修改試驗條件及存儲路徑及自動存儲試驗結(jié)果;
6、試驗過程中,可隨時通過軟件決定本次試驗是否有效,方便篩選試驗結(jié)果;
7、可設(shè)置操作口令,做到專機專人操作,避免無關(guān)人員誤操作;
8、試驗報告格式靈活可變,適用于不同用戶的不同需求;
9、可對一組試驗中曲線數(shù)據(jù)的有效與否進行人為選定;
10、試驗結(jié)果數(shù)據(jù)可導(dǎo)入EXECL,WORD文檔編輯;
11、過電流保護裝置有足夠的靈敏度,能夠保證試樣擊穿時在0.1S內(nèi)切斷電源;
12、儀器運行的持久性: 儀器可連續(xù)運行使用,不需為保護儀器而定期停機;
常規(guī)型號:
電壓擊穿試驗儀BDJC-10KV(1萬伏)主要用于薄膜材料,丙烯薄膜聚乙烯薄膜.聚酯薄膜,流延聚丙烯薄膜,一般厚度為1-3mm
電壓擊穿試驗儀BDJC-30KV(3萬伏)主要適用于橡膠,絕緣漆漆膜,聚氨酯,硫化橡膠等推薦可測厚度2-3mm
電壓擊穿試驗儀BDJC-50KV(5萬伏)主要用于電纜紙,電容器紙,云母,陶瓷,推薦可測厚度為2-3mm
電壓擊穿試驗儀BDJC-100KV(10萬伏)適用于玻璃,層壓材料,橡膠,樹脂,推薦可測厚度為2-5mm
電壓擊穿試驗儀BDJC-150KV(15萬伏) 適用于塑料、橡膠、層壓材料、薄膜、樹脂、云母、陶瓷、玻璃、絕緣漆等絕緣材料,推薦可測厚度為1-6mm
北廣公司以精美的產(chǎn)品、*的技術(shù)、精良的品質(zhì)、精心的服務(wù)贏得了廣大用戶和*,產(chǎn)品全國,擁有一大批國內(nèi)外著名科研院所及企業(yè)用戶,是國內(nèi)試驗機行業(yè)發(fā)展速度快的企業(yè)之一。
北京北廣精儀儀器設(shè)備有限公司自2012-06-12創(chuàng)立,規(guī)模逐步發(fā)展壯大,憑著過硬的生產(chǎn)技術(shù)、豐富的管理經(jīng)驗,優(yōu)質(zhì)的客戶服務(wù)和良好的企業(yè)信譽,在試驗機行業(yè)不斷進步。在短時間內(nèi)完成了企業(yè)創(chuàng)建、完善、發(fā)展完善的過程,試驗儀市場廣闊,產(chǎn)品已經(jīng)銷售到全國。