低溫脆性沖擊試驗(yàn)機(jī)廠家 儀器標(biāo)準(zhǔn):
本儀器是根據(jù)GB1682國(guó)家標(biāo)準(zhǔn)設(shè)計(jì)的,各項(xiàng)技術(shù)指標(biāo)符合HG 2-162-1965塑料低溫沖擊壓縮試驗(yàn)方法和GB5470-2008 塑料沖擊脆化溫度試驗(yàn)方法等國(guó)家標(biāo)準(zhǔn)的要求。
技術(shù)參數(shù):
1.控溫范圍:室溫 -70℃(室溫≤25℃)
2.恒溫精度:±0.3℃
3.降溫速度:0℃~﹣30℃ 約2.5℃/min
﹣30℃~﹣40℃ 約2.5℃/min
﹣40℃~﹣70℃ 約2.0℃/min
4.大外形尺寸:900×500×800mm(長(zhǎng)×寬×高)
5.工作室有效工作空間:280×170×120mm(長(zhǎng)×寬×高)
6.可裝試樣數(shù)量:1
7.數(shù)字計(jì)時(shí)器數(shù)字計(jì)時(shí)器:0秒 -99分鐘,分辨率1秒
8.冷卻介質(zhì):乙醇或其他不凍液
9.攪拌電機(jī):8W
10.工作電源:220V--240V,50Hz,1.5kW
11.工作溫度:≤25℃
適用行業(yè):
可以用來(lái)考核和確定電工、電子、汽車(chē)電器、材料等產(chǎn)品,在低溫環(huán)境條件下貯存和使用的適應(yīng)性,適用于學(xué)校,工廠,軍工,研位,等單位。
使用方法
1接通電源,溫控儀和計(jì)時(shí)器顯示燈亮。
2向冷井中注入冷凍介質(zhì)(一般為工業(yè)乙醇),其注入量應(yīng)保證夾持器的下端到液面的距離為75±10mm。
3將試樣垂直夾在夾持器上。夾的不宜過(guò)緊或過(guò)松,以防止試樣變形或脫落。
4按下夾持器,開(kāi)始冷凍試樣,同時(shí)啟動(dòng)時(shí)序控制開(kāi)關(guān)(或按動(dòng)秒表)計(jì)時(shí)。試樣冷凍時(shí)間規(guī)定為3.0±0.5min。試樣冷凍期間,冷凍介質(zhì)溫度波動(dòng)不得超過(guò)±1℃。
5提起升降夾持器,使沖擊器在半秒鐘內(nèi)沖擊試樣。
6取下試樣,將試樣按沖擊方向彎曲成180°,仔細(xì)觀察有無(wú)破壞。
7試樣經(jīng)沖擊后(每個(gè)試樣只準(zhǔn)沖擊一次),如出現(xiàn)破壞時(shí),應(yīng)提高冷凍介質(zhì)的溫度,否則降低其溫度,繼續(xù)進(jìn)行試驗(yàn)。 溫度,如這兩個(gè)結(jié)果相差不大于1℃時(shí),即試驗(yàn)結(jié)束。
注意事項(xiàng)
1在試驗(yàn)過(guò)程中不能切斷冷卻循環(huán),否則會(huì)產(chǎn)生不制冷的效果。
2氣缸壓力在出廠前已調(diào)節(jié)好,不能任意變動(dòng)。
Structural principle
A. The equipment consists of the main body of the refrigeration compressor, heating device, electronic control box, cooling tank, cooling medium circulation system and automatic alarm device. After starting the refrigeration switch, the compressor starts to work and the refrigeration system enters the formal working state. The refrigeration compressor works continuously. When approaching the set temperature, the heating device in the cooling tank begins to provide heat proportionally to balance the excess cold generated by the refrigeration system in order to achieve the goal of constant temperature. Stirring can make the cooling medium in the cooling tank circulate continuously and make the temperature uniform.
B. Sample holder
Four specimens (rubber) are clamped on one side and fifteen specimens (plastic) are clamped on the other.
C. Impulse Device
The impact device consists of an impact hammer and a self-locking mechanism.
D. impactor
The radius of the impact head is 1.6 + 0.1 mm.
When impacting, the gap between the impacting head and the sample holder is 6.4 + 0.3 mm.
The distance between the center line of the impact head and the sample holder is 8 +0.3mm.
結(jié)構(gòu)原理
A、本設(shè)備由制冷壓縮機(jī)主機(jī)體、加熱裝置、電子控制箱、冷卻槽、冷卻介質(zhì)循環(huán)系統(tǒng)、自動(dòng)報(bào)警裝置等部分組成。啟動(dòng)制冷開(kāi)關(guān)后,壓縮機(jī)開(kāi)始工作,制冷系統(tǒng)進(jìn)入正式工作狀態(tài)。制冷壓縮機(jī)連續(xù)不斷的工作,當(dāng)接近設(shè)定溫度時(shí),冷卻槽中的加熱裝置開(kāi)始按比例提供熱量,用以平衡制冷系統(tǒng)產(chǎn)生的多余冷量,以達(dá)到恒溫的目的。攪拌可使冷卻槽內(nèi)的冷卻介質(zhì)不斷循環(huán),使溫度均勻*。
B、試樣夾持器
試樣一邊夾持4個(gè)試樣(橡膠類(lèi)),另一邊夾持15個(gè)試樣(塑料類(lèi))。
C、沖擊裝置
沖擊裝置由沖chong錘和自鎖機(jī)構(gòu)組成。
D、沖擊器
沖擊頭半徑為1.6±0.1mm;
沖擊時(shí),沖擊頭和試樣夾持器之間間隙為6.4±0.3mm;
沖擊頭的中心線(xiàn)與試樣夾持器之間的距離為8±0.3mm。